UL 1007 22 AWG PVC Hook-Up Wire — 80°C 300V for Appliance Control Board Internal Wiring

UL AWM Style 1007 22 AWG PVC hook-up wire rated 80°C and 300 Vac, with 15-mil minimum average insulation for appliance internal wiring and control-board harness applications. Solid or stranded conductor, Horizontal Flame. Conductor material, colour, and packaging confirmed per order.

Categories: ,

UL 1007 22 AWG PVC Hook-Up Wire Overview

UL AWM Style 1007 is a single-conductor PVC insulated wire construction, supplied by CableApex as a factory-direct manufacturer. This page focuses specifically on the 22 AWG configuration within Style 1007’s broader 32 AWG–16 AWG conductor range. The wire is rated 80°C and 300 Vac, with extruded PVC insulation. This is a dedicated 22 AWG procurement page, distinct from our other UL 1007 pages covering different AWG sizes, bulk supply, custom colours, and power-supply application context.

UL Style 1007 22 AWG PVC wire cross-section diagram showing conductor and 15 mil insulation wall

80°C / 300 Vac Style 1007 Construction

ParameterUL Style 1007
UL Subject / Section758, Section 1
ConstructionSingle conductor with extruded insulation
Featured Conductor Size22 AWG
UL Style Conductor Range32 AWG – 16 AWG
Conductor FormSolid or stranded
Rated Temperature (Maximum)80°C
Voltage Rating300 Vac
Flame RatingHorizontal flame
InsulationExtruded PVC, 15 mil min. average / 13 mil min. at any point
Optional Oil Designation60°C or 80°C, where qualified
MarkingGeneral; tags may optionally indicate 600 V Peak — For Electronic Use Only
UL-Defined UseInternal wiring of appliances
Commercial Application ContextControl-board / appliance harness wiring where the end-equipment design permits Style 1007
RoHS / REACHConfirmed during quotation according to ordered materials and documentation requirements

22 AWG Appliance Internal Wiring

This page focuses specifically on the 22 AWG configuration within UL Style 1007’s 32 AWG–16 AWG conductor range. We do not publish ampacity, allowable current, maximum current, or a recommended breaker or fuse size for 22 AWG — current-carrying requirements depend on the equipment design and applicable end-equipment evaluation, not on AWG alone. This page does not characterize 22 AWG as a “signal” or “low-to-medium current” wire; UL Style 1007 does not establish signal performance, impedance, or data-transmission characteristics.

Solid or Stranded Conductor Options

UL Style 1007 permits solid or stranded conductor construction; this page does not present 22 AWG as universally stranded. We do not publish strand count, strand diameter, bunching pattern, lay length, or conductor resistance, as none of these are established by the Style-level record. Conductor material and finish are also not established at the Style level — this page does not describe UL 1007 as universally tinned copper or bare copper; conductor material or plating should be specified when requesting a quotation. This page also does not claim 22 AWG is flexible, high-flex, or extra-flexible as a universal property — the Style’s solid-or-stranded permission does not establish one flexibility classification.

15-Mil Minimum Average PVC Insulation

The conductor is insulated with extruded PVC at a minimum average thickness of 15 mils and a minimum thickness of 13 mils at any point. This is precise UL terminology — a minimum average thickness, not a nominal production dimension — and we do not calculate or publish a finished outside diameter from AWG and insulation thickness, as conductor geometry and manufacturing tolerances are not part of the confirmed technical basis for this page.

UL 1007 22 AWG PVC wire routed for control board connection inside appliance enclosure

Control-Board Connections Inside Appliances

The supplied UL Style 1007 record does not specifically state “control board wiring” as its formal use — the UL-defined use is internal wiring of appliances. Control-board positioning on this page is a commercial application context, not a separate UL Use statement: UL 1007 may be specified for control-board connections inside appliances, appliance control-board internal wiring, and internal appliance harnesses connected to control boards, where the end-equipment design and applicable requirements permit Style 1007. This page does not claim that UL 1007 is “specifically certified for control boards,” and does not imply that every control board or electronic product automatically accepts Style 1007 wire.

UL 1007 Technical Specifications

See the specification table above for the complete confirmed ratings applicable to this featured 22 AWG product.

Appliance Harness and Component Wiring

UL Style 1007’s confirmed use is internal wiring of appliances. This page does not broaden the use into general electrical or electronic equipment wiring, industrial control wiring, control-panel wiring, field wiring, building wiring, or branch circuits. Where wire-harness assembly is discussed, it refers to appliance internal wiring harness production using the qualified Style 1007 component wire — UL 1007 applies to the component wire itself, not automatically to a complete assembled harness. Power-supply internal lead connections may be a secondary application example only where the power-supply assembly is part of qualified end equipment and Style 1007 is permitted; buyers with a power-supply-specific focus should see our dedicated UL 1007 power-supply wire page.

What 22 AWG Does and Does Not Define

Choosing 22 AWG establishes the conductor size within the Style 1007 range — it does not by itself establish a bend radius, routing performance, stripping performance, or crimp performance. Where a design specifies 22 AWG, buyers should confirm the required finished dimensions and routing space during quotation; we do not publish a minimum or recommended bend radius. We also do not claim guaranteed easy stripping, guaranteed crimp performance, or reduced assembly rework as universal properties of this construction — processing performance depends on the actual conductor construction, finished dimensions, tooling, and termination system. For harness production, buyers should confirm conductor construction, finished dimensions, strip requirements, and terminal or crimp information where relevant.

Optional Oil Rating and 600V Peak Tag

UL Style 1007 permits an optional 60°C or 80°C oil designation, available only where included in the qualified construction — this page does not state that every UL 1007 22 AWG order is automatically oil resistant. Separately, the Style permits a tag statement indicating “600 V Peak — For Electronic Use Only.” This is not equivalent to a 600 Vac continuous rating; the primary continuous voltage rating for this page remains 300 Vac throughout.

What to Specify When Ordering UL 1007 22 AWG Wire

To provide an accurate quotation for UL 1007 22 AWG PVC hook-up wire, please specify:

  • Confirmation of 22 AWG as the required gauge
  • Solid or stranded conductor
  • Conductor material or plating requirement
  • Insulation colour
  • Operating temperature
  • Operating voltage
  • Optional oil designation, if required
  • Required finished OD or routing-space limit, if applicable
  • Strip length or processing requirement, if relevant
  • Terminal or crimp specification, if relevant
  • Marking requirement
  • Order quantity
  • Packaging requirement
  • UL documentation requirement, including RoHS / REACH if needed
  • Appliance type
  • Control-board / internal wiring application
  • Shipping destination

Send this information and we respond with a quotation within 12 business hours. Production lead time depends on the confirmed construction and order quantity, and shipping options and applicable Incoterms are confirmed during quotation according to destination.

Macro cross-section of UL 1007 22 AWG PVC wire showing conductor and thin extruded PVC wall

UL Marking and Documentation

Qualifying UL AWM Style 1007 constructions can be supplied through the relevant qualified manufacturing scope for this Style. UL marking and documentation are confirmed according to the qualified Style 1007 construction supplied for the order and are not identical across every commercial variation. RoHS and REACH are separate regulatory frameworks from UL recognition; applicable RoHS / REACH documentation requirements can be confirmed according to the ordered construction.

Browse our UL1007 Wire category, or see our broader PVC Insulated Wire range for related constructions.

Scroll to Top