UL 3122 Silicone Rubber Wire — 200°C / 300V AC / Lacquered Braid / 26–16 AWG — Vietnam
UL AWM Style 3122 is a single-conductor extruded silicone rubber insulated wire with a lacquered braid outer covering, rated at 200°C and 300V AC under UL Subject 758. The insulation uses extruded silicone rubber at 15 mils minimum average wall thickness, with a lacquered cotton or fiberglass braid applied over the silicone rubber as the outer covering. The conductor range covers 26 AWG to 16 AWG in solid or stranded construction. The permitted use is internal wiring of appliances. Export supply: CIF Ho Chi Minh City.
UL 3122 is the 300V lacquered braid variant in the UL 3071 / 3122 / 3135 / 3172 silicone rubber family. The lacquered braid outer covering provides a dry, non-tacky surface and mechanical protection compared to bare silicone rubber, while maintaining the 200°C temperature rating. For 300V bare silicone rubber in the 26–12 AWG range, see UL 3135. For 600V silicone rubber with fiberglass braid, see UL 3172.
Product Specifications — UL AWM Style 3122
| Parameter | Specification |
|---|---|
| UL AWM Style | 3122 |
| UL Subject | 758, Section 3 |
| Temperature Rating | 200°C maximum |
| Voltage Rating | 300V AC |
| AWG Range | 26 AWG – 16 AWG, solid or stranded |
| Insulation Material | Extruded silicone rubber (SR) |
| Insulation Thickness | 15 mils min average / 13 mils min at any point |
| Outer Covering | Lacquered cotton or fiberglass braid |
| Conductor | Solid or stranded copper; bare, tinned, or nickel-plated |
| Flame Rating | Horizontal flame |
| UL Recognition | UL Recognized Component — file on record |
| Permitted Use | Internal wiring of appliances |
| RoHS / REACH | Documentation available on request |
UL 3122 Silicone Family Comparison
| Style | Temp | Voltage | AWG | Outer Covering | Use Restriction |
|---|---|---|---|---|---|
| UL 3071 | 200°C | 600V | 18–13 AWG | SF-2 type covering | Internal wiring of appliances |
| UL 3122 (this page) | 200°C | 300V | 26–16 AWG | Lacquered cotton or fiberglass braid | Internal wiring of appliances |
| UL 3135 | 200°C | 600V | 26–12 AWG | None — bare SR | Totally enclosed only |
| UL 3172 | 200°C | 600V | 26–18 AWG | Glass or aramid braid (SF-2) | Internal wiring of appliances |
Applications in Vietnam
Transformer coil lead wiring in appliance OEM production
Vietnamese appliance OEMs assembling transformers for export require UL-recognized internal lead wire for coil-to-terminal connections. UL 3122’s 300V rating covers the secondary side of step-down and isolation transformers used in household appliances, while the lacquered braid provides a manageable surface for hand-routing through tight coil former channels. The 26–18 AWG fine-gauge end of the range suits small transformer coil exit wires where conductor current is low but 200°C insulation performance is required.
Motor and solenoid coil lead connections in heating equipment
Vietnamese heating equipment manufacturers — electric ovens, drying equipment, and process heaters — use UL 3122 for motor coil lead connections and solenoid valve wiring inside equipment enclosures where the wire routing location temperature exceeds the 105°C limit of standard PVC wire. The lacquered braid outer covering provides a non-tacky surface that handles cleanly during assembly compared to bare silicone rubber, which can attract particulate contamination during production.
Compact appliance wiring harnesses requiring 200°C insulation
Vietnamese compact appliance OEMs assembling products for markets requiring UL component recognition use UL 3122 for internal wiring harnesses where the circuit voltage is within the 300V limit and the routing temperature requires 200°C-rated insulation. The fine AWG range (26–16 AWG) and lacquered braid outer covering suit hand-assembly wiring harness production in compact appliance enclosures. Confirm that the application meets UL 3122’s permitted use of internal wiring of appliances before specifying.
Other applications
- Sensor and thermocouple lead connections in high-temperature appliance enclosures — confirm voltage and current at enquiry
- Internal control circuit wiring at 300V in enclosed heating equipment
- OEM appliance internal wiring harnesses requiring lacquered braid surface for assembly handling
Key Features
Product
- UL AWM Style 3122, 200°C, 300V AC
- UL Recognized Component — file on record
- Conductor range: 26 AWG – 16 AWG
- SR insulation: 15 mils avg / 13 mils min
- Lacquered cotton or fiberglass braid outer covering
- Horizontal flame rating
- RoHS / REACH documentation on request
Supply for Vietnam
- Export supply — CIF Ho Chi Minh City
- Transit approx. 10–14 days
- UL compliance documentation on request
- MOQ 500 m per AWG
- Mixed AWG orders accepted
- Lead time confirmed at enquiry stage
Ordering Information
Specify AWG (26–16 AWG), conductor type (bare / tinned / nickel-plated), braid type (cotton or fiberglass), colour, and quantity. MOQ 500 m per AWG. UL recognition documentation and RoHS Declaration available on request. Sample from 10 m. Response within 24 hours.
Request CIF Ho Chi Minh City pricing. Provide AWG, quantity, and required documentation. Response within 24 hours. Contact us.