UL 1283 PVC Internal Wiring Wire 8 AWG — Entry Gauge of the Style, 105°C at 600 Vac with 60-mil Wall
UL 1283 in 8 AWG is a single-conductor internal wiring wire with extruded PVC insulation, rated 105°C maximum at 600 Vac, available in solid, stranded or braided conductor construction. As the finest gauge in the style’s 8–2 AWG range, 8 AWG is where UL 1283 begins — and where it picks up directly from the heavy end of UL 1056, which stops at 10 AWG. The two styles share an identical 60 mils minimum average PVC wall and the same 105°C / 600 Vac rating, so a design that needs conductors spanning both ranges can maintain consistent insulation characteristics across the full span. CableApex supplies UL 1283 8 AWG as a UL Recognized Component — file on record.

Where UL 1283 Takes Over from UL 1056
| Specification | UL 1056 | UL 1283 (this page) |
|---|---|---|
| Conductor range | 20–10 AWG | 8–2 AWG (starts at 8 AWG) |
| Conductor construction | Stranded only | Solid, stranded, or braided |
| PVC wall | 60 mils avg / 54 mils min | 60 mils avg / 54 mils min (identical) |
| Rating | 105°C / 600 Vac | 105°C / 600 Vac (identical) |
| Permitted use | Refrigerating equipment only | General internal wiring |
| Peak voltage tag | Not listed | Optional 2500 V peak, electronic use only |
UL 1283 8 AWG Specifications
| Item | Specification |
|---|---|
| UL Style | 1283 — single conductor with extruded insulation |
| Temperature Rating | 105°C maximum |
| Voltage Rating | 600 Vac; optional tag: 2500 V peak — for electronic use only |
| Conductor | 8 AWG, solid or stranded, or braided (40–20 AWG strands); style range 8–2 AWG |
| Insulation | Extruded PVC, 60 mils minimum average thickness, 54 mils minimum at any point |
| Flame Rating | Horizontal flame; VW-1 vertical flame test available |
| Oil Rating | Optional — 60°C or 80°C oil resistant |
| UL Recognition | UL Recognized Component — file on record |
| Marking | Per UL Subject 758 marking requirements |
| Permitted Use | Internal wiring; tags may indicate 2500 V peak — for electronic use only |
| RoHS / REACH | Documentation available on request |
Conductor Choice at the Fine End of the Range
At 8 AWG, the three conductor constructions permitted under Style 1283 produce genuinely different handling characteristics. Solid 8 AWG is stiff and holds its shape once formed, which suits short fixed runs between a terminal block and a mounted component where the wire route will not change over the equipment’s service life. Stranded 8 AWG offers conventional flexibility and is the general-purpose choice for routed internal wiring. Braided 8 AWG — built from 40–20 AWG fine strands — is markedly more supple than either alternative and is worth specifying where the conductor must be dressed around structural members, where the equipment design requires the wire to be disconnected and refitted during servicing, or where the installation transmits vibration to the conductor. All three carry identical UL recognition, insulation wall and ratings, so the selection is purely a handling and installation decision.
Applications
Within its permitted use — internal wiring, with the optional 2500 V peak electronic use tag — UL 1283 8 AWG suits internal power feeds, sub-panel distribution conductors and bus connections inside equipment enclosures operating at up to 600 Vac with ambient temperatures reaching 105°C. Where the tag marking 2500 V peak — for electronic use only is required for internal electronic circuits, specify it at time of order. Where the wiring contacts oil inside the equipment, the optional 60°C or 80°C oil-resistant rating applies. Equipment-type-specific installations such as machine tools or control cabinets fall outside the explicit permitted use description; confirm application suitability before specifying for those end uses.
Key Features
- Entry gauge of Style 1283 — picks up where UL 1056 ends at 10 AWG
- Three conductor options: solid, stranded, or braided (40–20 AWG strands)
- 60 mils average PVC wall shared with UL 1056 for consistent insulation across ranges
- Optional 2500 V peak electronic use tag available
- Horizontal flame; VW-1 vertical flame test available
- UL Recognized Component — file on record
Request a Quote
CableApex supplies UL 1283 8 AWG from 100 m per color in solid, stranded or braided conductor construction and responds to B2B inquiries within 12 hours. Specify conductor construction, 2500 V peak tag option and oil rating if applicable when submitting your inquiry below.
Other UL 1283 sizes: 6 AWG · 4 AWG · UL 1056 PVC Wire (20–10 AWG, refrigerating equipment)