UL 1015 PVC Insulated Hook-up Wire (105°C / 600V)

UL AWM Style 1015 · 105°C maximum · 600 Vac / 750 Vdc · 30 AWG–2000 kcmil · extruded PVC · horizontal flame · UL Recognized Component — file on record · internal wiring of appliances · factory supply · 12-hr B2B quote

UL AWM Style 1015 — PVC Hook-Up Wire for Protected Internal Wiring

UL AWM Style 1015 is a PVC-insulated single-conductor hook-up wire for the protected internal wiring of appliances and electrical equipment, covered under UL Subject 758, Section 1. The Style supports temperature classes of 80°C, 90°C, or 105°C, at 600 Vac or 750 Vdc, across a conductor range from 30 AWG to 2000 kcmil. This page focuses on the marketed 105°C / 600V construction. Other constructions within the UL 1015 Style scope are available and should be confirmed at the quotation stage. CableApex supplies UL 1015 PVC wire from factory production, with conductor options, custom colours, spool lengths, and documentation confirmed according to the ordered construction.

UL AWM Style 1015 PVC hook-up wire installed inside protected electrical equipment enclosure for appliance internal wiring application

UL AWM Style 1015 — Key Specifications

ParameterValue per UL Style 1015 File
UL Style NumberAWM 1015
Temperature Rating80, 90, or 105°C maximum — marketed construction: 105°C maximum
Voltage Rating600 Vac or 750 Vdc — marketed construction: 600 Vac
Conductor30 AWG – 2000 kcmil, solid or stranded
Insulation MaterialExtruded PVC
Wall Thickness (30–9 AWG)30 mils (0.76 mm) min average / 27 mils (0.69 mm) min at any point
Wall Thickness (8–7 AWG)45 mils (1.14 mm) min average / 40 mils (1.02 mm) min at any point
Wall Thickness (6–2 AWG)60 mils (1.52 mm) min average / 54 mils (1.37 mm) min at any point
Wall Thickness (1–4/0 AWG)80 mils (2.03 mm) min average / 72 mils (1.83 mm) min at any point
Flame RatingHorizontal flame
Oil ResistanceOptional — 60°C or 80°C oil resistance available as a construction option
UL RecognitionUL Recognized Component — file on record
Permitted Use (per UL Style file)Internal wiring of appliances

UL AWM Style 1015 PVC wire cut-end close-up showing stranded copper conductor and extruded PVC insulation wall per UL Subject 758

Typical Construction Data — 30–9 AWG Range

The AWG sizes below fall within the 30–9 AWG insulation class (30 mils minimum average wall thickness). Conductor stranding, outer diameter, and resistance figures represent typical factory production values for these constructions. Final dimensions, conductor construction, markings, packaging, and documentation depend on the ordered construction and confirmed production specification. These values do not represent the complete UL 1015 conductor range.

Gauge (AWG)Conductor StrandingInsulation Thickness (mm)Outer Diameter (mm)Max Resistance (Ω/km)
24 AWG11/0.160.762.2094.2
20 AWG21/0.180.762.5536.7
18 AWG34/0.180.762.8523.2
14 AWG41/0.250.763.558.96

Direct Factory Supply — UL AWM Style 1015

  • Direct factory communication: UL 1015 PVC wire orders are handled directly from the production facility, with no intermediate traders — supporting efficient lead-time coordination and technical clarification before and during production.
  • Custom colour and spool length options: PVC jacket colour and spool length can be produced to the buyer’s specification. Custom colour requests and applicable minimum order quantities are confirmed at the enquiry stage.
  • AWG and stranding options: Standard production covers commonly ordered AWG sizes in the fine-wire range; additional sizes within the full 30 AWG–2000 kcmil Style scope are available upon confirmation. Conductor stranding options can be discussed according to production capability.
  • Production quality control: Dimensional checks and electrical tests are applied during production to verify insulation wall thickness, continuity, and voltage withstand consistent with the ordered construction.
  • Export documentation coordination: Commercial Invoice, Packing List, Certificate of Origin (CCPIT), and Bill of Lading are provided as standard. UL Style documentation is available according to the ordered and confirmed construction. RoHS and REACH documentation is available on request where applicable to the order.

For 300V PVC AWM hook-up wire applications, UL AWM Style 1007 (80°C / 300V, 32–16 AWG, extruded PVC, 15 mils minimum wall) is available as the lower-voltage class alternative for appliance internal wiring that does not require the 600V insulation level of UL 1015.

UL AWM Style 1015 cross-section technical diagram with callout lines showing stranded copper conductor, extruded PVC insulation wall thickness, and key ratings per UL Subject 758

Related UL AWM Styles for Comparison

Buyers evaluating UL 1015 may also consider: UL AWM 1007 (80°C / 300V PVC, 32–16 AWG — lower-voltage appliance internal wiring); UL AWM 1569 (80–105°C / 300V PVC, 30–2 AWG — 300V class with 15 mils thin wall for compact installations); UL AWM 10269 (80–105°C / 1,000 Vac or 1,250 Vdc PVC, 30 AWG–2000 kcmil — higher-voltage class PVC alternative); and UL AWM 3271 (125°C / 600 Vac or 750 Vdc XLPE, 30 AWG–2000 kcmil — higher-temperature motor lead and internal wiring alternative).

Scroll to Top