UL 1056 Refrigerating Equipment Wire 16 AWG · PVC · 600V · 105°C

UL 1056 · 105°C maximum · 600 Vac · 16 AWG stranded (style range 20–10 AWG) · Extruded PVC 60 mils minimum average wall · Horizontal flame; VW-1 vertical flame test available · Optional 60°C / 80°C oil resistant · UL Recognized Component — file on record · Internal wiring of indoor or outdoor refrigerating equipment · Quotes within 12 hours

Category:

UL 1056 Refrigerating Equipment Wire 16 AWG — 600 Vac, Stranded PVC, Indoor and Outdoor Rated

UL 1056 in 16 AWG delivers 600 Vac insulation in a stranded single conductor with extruded PVC wall rated at 105°C maximum, recognised for internal wiring of both indoor and outdoor refrigerating equipment. The stranded-only construction at 16 AWG provides the flexibility needed for wiring harnesses that must route around compressor fittings, fan motor brackets and cabinet framing in split-system and self-contained refrigerating units. CableApex supplies this size as a UL Recognized Component — file on record.

UL 1056 16 AWG cross-section diagram PVC 60 mils average wall vs UL 1015 30 mils, 105C 600V

UL Recognized Component — file on record. Style 1056 appliance wiring material evaluated under UL Subject 758.

UL 1056 vs. UL 1015 at 16 AWG: Choosing the Right Style

SpecificationUL 1056 (this page)UL 1015
Temperature105°C maximum80 / 90 / 105°C
Voltage600 Vac600 Vac / 750 Vdc
PVC Wall (16 AWG)60 mils avg / 54 mils min30 mils avg / 27 mils min
ConductorStranded onlySolid or stranded
Oil option60°C or 80°C optional60°C or 80°C optional
Permitted useRefrigerating equipment onlyGeneral appliance internal wiring

UL 1056 16 AWG Specifications

ItemSpecification
UL Style1056 — single conductor with extruded insulation
Temperature Rating105°C maximum
Voltage Rating600 Vac
Conductor16 AWG, stranded only (style range 20–10 AWG stranded)
InsulationExtruded PVC, 60 mils minimum average thickness, 54 mils minimum at any point
Flame RatingHorizontal flame; VW-1 vertical flame test available
Oil RatingOptional — 60°C or 80°C oil resistant
UL RecognitionUL Recognized Component — file on record
MarkingPer UL Subject 758 marking requirements
Permitted UseInternal wiring of indoor or outdoor refrigerating equipment
RoHS / REACHDocumentation available on request

UL 1056 16 AWG wire routed inside outdoor condensing unit for internal refrigerating equipment wiring

Applications

Within its permitted use — internal wiring of indoor or outdoor refrigerating equipment — UL 1056 16 AWG suits fan motor leads, internal control circuit conductors and intermediate-gauge power wiring in residential and light-commercial refrigerating units, including split-system condensing units and self-contained display cases installed outdoors. The outdoor rating makes this size suitable for condensing unit control wiring that must meet the same UL component recognition as the indoor evaporator section. Where the wiring contacts refrigerant oil, specify the 60°C or 80°C oil-resistant option at time of order. For applications outside refrigerating equipment, confirm application suitability before specifying.

Key Features

  • Indoor and outdoor refrigerating equipment recognition in a single style
  • 60 mils average PVC wall — double the thickness of UL 1015 at the same gauge
  • Optional 60°C or 80°C oil resistant rating
  • Stranded construction for flexible routing in compressor and fan wiring
  • Horizontal flame; VW-1 vertical flame test available
  • UL Recognized Component — file on record

Request a Quote

CableApex supplies UL 1056 16 AWG from 100 m per color and responds to B2B inquiries within 12 hours with pricing, oil-rating option, lead time and packing details. Submit your specification through the form below.

Related UL styles: UL 1056 14 AWG Refrigeration Wire · UL 1015 PVC Wire (general appliance 600 V) · UL 1032 PVC Wire (1000 Vac / 1200 Vdc)