UL 1333 FEP Appliance Wire 18 AWG · 150°C · 300V

UL 1333 · 150°C maximum · 300 Vac; optional 600 V peak electronic tag · 18 AWG solid, stranded or Litz cable magnet wire (style range 30–10 AWG) · Extruded FEP 13 mils minimum average wall, uniform across the range · Optional covering: FEP 10 mils minimum, or glass braid 7 mils minimum · Horizontal flame; VW-1 vertical flame test available · Optional 80°C oil and gasoline resistance · UL Recognized Component — file on record · Internal wiring of appliances · Quotes within 12 hours

Category:

UL 1333 FEP Appliance Wire 18 AWG — One Wall Thickness Across the Whole 30 to 10 AWG Range

UL 1333 in 18 AWG is a single-conductor appliance wiring material with extruded FEP insulation, rated 150°C maximum at 300 Vac with a horizontal flame rating. Unlike UL 1330 and UL 1331, which each specify three wall brackets that step up with conductor size, UL 1333 specifies one figure for its entire range: 13 mils minimum average thickness, 12 mils minimum at any point, from 30 AWG through 10 AWG. At 18 AWG that means the same wall as a 30 AWG signal conductor and the same wall as a 10 AWG power lead. CableApex supplies UL 1333 18 AWG as a UL Recognized Component — file on record.

UL 1333 constant 13 mil FEP wall diagram across 30 to 10 AWG conductor range with 18 AWG highlighted

UL Recognized Component — file on record. Style 1333 appliance wiring material evaluated under UL Subject 758.

What a Constant Wall Means at Different Gauges

When insulation thickness does not scale with conductor size, the ratio between wall and conductor changes continuously across the range. At the fine end, 13 mils of FEP on a 30 AWG conductor is generous in proportion — the insulation dominates the cross-section and the wire tolerates handling, clamp pressure and edge contact well for its diameter. At 18 AWG the proportion is balanced: enough wall for the mechanical demands of a routed appliance lead, without the diameter penalty of a bracket-scaled style. Toward 10 AWG the same 13 mils becomes proportionally lean around a much larger conductor, which keeps the finished diameter compact but leaves less margin for abrasion, making the optional covering more worth considering at the heavy end than at the fine end.

The practical consequence for a design is that gauge can be changed within this style without recalculating insulation dimensions from a bracket table. A circuit revised from 20 AWG to 18 AWG, or from 18 AWG to 16 AWG, keeps the same wall figure and the finished diameter changes only by the conductor difference. In a style with brackets, the same revision can cross a boundary and change the wall unexpectedly.

Constant 13-mil Wall Across the Range

Conductor sizeFEP wallWall relative to conductorPractical note
30–24 AWG13 mils avg / 12 mils minGenerousRobust for gauge; covering rarely needed
22–16 AWG (18 AWG here)13 mils avg / 12 mils minBalancedCompact diameter for routed appliance leads
14–10 AWG13 mils avg / 12 mils minLeanConsider covering where abrasion is a factor

UL 1333 18 AWG Specifications

ItemSpecification
UL Style1333 — single conductor with extruded insulation
Temperature Rating150°C maximum
Voltage Rating300 Vac; tag may also indicate 600 Volts Peak for electronic use only
Conductor18 AWG, solid or stranded, or Litz cable magnet wire, R/C (OBMV2) rated minimum 150°C (style range 30–10 AWG)
InsulationExtruded FEP, 13 mils minimum average thickness, 12 mils minimum at any point — uniform across the full conductor range
Optional CoveringExtruded FEP, 10 mils minimum at any point; or glass braid, 7 mils minimum at any point
Flame RatingHorizontal flame; VW-1 vertical flame test available
Oil RatingOptional — 80°C oil resistant
Gasoline ResistanceOptional
UL RecognitionUL Recognized Component — file on record
MarkingPer UL Subject 758 marking requirements; Litz product additionally marked “Litz conductors are manufactured using solderable magnet wire”
Permitted UseInternal wiring of appliances
RoHS / REACHDocumentation available on request

UL 1333 18 AWG FEP wire with mixed gauges in single appliance harness sharing the same insulation wall

Where the Covering Options Earn Their Place

Because the base wall does not increase with gauge, the two covering options carry more weight in this style than in a bracket-scaled one. An extruded FEP covering at 10 mils minimum at any point roughly doubles the fluoropolymer around the conductor, which restores a substantial abrasion margin while keeping the smooth low-friction outer surface that helps the lead pull through passages. A glass braid at 7 mils minimum takes a different approach, presenting a fibrous outer face that wears sacrificially and stands up to contact with hot metalwork better than a smooth polymer surface, at the cost of higher pull friction. At 18 AWG in a clean routed harness neither is usually necessary; where the lead runs against a bracket edge or through a compartment opened during service, one of them generally is.

Applications

Within its permitted use — internal wiring of appliances — UL 1333 18 AWG suits routed internal leads, control and light-duty power connections in appliances operating at 300 Vac in zones reaching 150°C, and internal electronic circuits where the 600 V peak tag applies. The constant wall makes it straightforward to specify across several gauges in one harness without tracking bracket boundaries. Litz construction is available for high-frequency winding leads at this gauge. Optional 80°C oil resistance and optional gasoline resistance are available where lubricant or fuel contact is expected. For applications outside internal appliance wiring, confirm application suitability before specifying.

Key Features

  • One wall figure across 30–10 AWG — no bracket table to track
  • Gauge revisions within the style do not change the insulation dimension
  • 13 mils wall at 18 AWG gives a compact diameter for routed appliance leads
  • Covering options restore abrasion margin where the run demands it
  • 300 Vac base rating with optional 600 V peak electronic use tag
  • UL Recognized Component — file on record

Macro cut end of UL 1333 18 AWG showing uniform 13 mil FEP insulation wall and stranded copper conductor

Request a Quote

CableApex supplies UL 1333 18 AWG from 100 m per color and responds to B2B inquiries within 12 hours. Specify conductor construction (solid, stranded or Litz), colors, covering option, the 600 V peak tag if required, and any oil or gasoline requirements through the form below.

Other UL 1333 sizes: 20 AWG · 22 AWG · UL 1331 FEP Wire (150°C / 600 Vac)