UL 5476 450°C Mica Tape Wire for Vietnam and Indonesia
UL 5476 is a mica tape insulated wire with a glass braid outer covering, rated 450°C and 600V AC under UL AWM Style 5476, produced under UL Follow-Up Service File No. E333030. UL 5476 occupies the same 450°C / 600V specification position as UL 5107 and UL 5335 — the same maximum continuous temperature rating, the same voltage rating, and the same mica tape insulation technology that provides inorganic mineral insulation stability at temperatures that destroy all organic polymer insulations. The distinction between UL 5476 and UL 5107 is construction geometry: the mica tape wrap and glass braid construction of UL 5476 is engineered to produce a smaller overall wire diameter at the same AWG size and insulation rating than the UL 5107 glass braid construction, making UL 5476 the specification for 450°C / 600V applications where the installed space available for wire routing is constrained below the OD that UL 5107 would occupy at the same AWG.
This is a specific but practically important application constraint in Vietnamese and Indonesian industrial furnace and kiln construction. When a kiln or furnace is built, the ceramic conduit tubes embedded in the refractory lining, the penetration slots cut through the insulation panels, and the structural channel dimensions in the furnace frame are all fixed at the construction stage and cannot be enlarged during equipment operation without major refractory rework. When the wire routing through these fixed-geometry paths must be replaced — during scheduled element replacement, after insulation damage, or as part of a furnace upgrade — the replacement wire must fit through the existing path geometry. If the existing geometry was designed for a compact wire OD and UL 5107’s larger glass braid construction does not fit, UL 5476 is the specification that can pass through the same existing path while delivering identical 450°C / 600V insulation performance.
Vietnamese furnace and kiln builders and maintenance contractors refer to UL 5476 as dây mica nhà sản xuất (mica wire manufacturer supply) — sourcing factory-direct from Yangzhou for new furnace builds where compact routing geometry requires UL 5476 over UL 5107. Indonesian industrial heating equipment suppliers and furnace maintenance contractors source UL 5476 as kabel mica harga grosir (mica cable wholesale price) at factory-direct pricing from CableApex. CableApex exports UL 5476 CIF Ho Chi Minh City and CIF Surabaya from Yangzhou.
Product Specifications — UL 5476
| Parameter | Specification |
|---|---|
| UL AWM style | 5476 |
| Insulation | Mica tape wrap |
| Outer covering | Glass braid |
| Temperature rating | 450°C continuous |
| Voltage rating | 600V AC |
| Key advantage vs UL 5107 | Smaller overall diameter at same AWG and voltage rating |
| Conductor | Stranded nickel-plated or bare copper |
| Flame rating | Horizontal flame |
| UL file number | E333030 |
| Compliance | RoHS, REACH |
UL 5476 vs UL 5107 vs UL 5335 — When to Specify UL 5476
| Property | UL 5476 (this product) | UL 5107 | UL 5335 |
|---|---|---|---|
| Temperature rating | 450°C | 450°C | 450°C |
| Voltage rating | 600V AC | 600V AC | 600V AC |
| Insulation | Mica tape | Mica tape | Mica tape |
| Outer covering | Glass braid | Glass braid | Glass braid |
| Overall diameter at same AWG | Smaller | Standard | Standard |
| Specify when | Routing path OD constraint — existing ceramic conduit, tight penetration slot, or narrow channel | Standard open routing or conduit with adequate clearance | Where equipment documentation specifies UL 5335 |
Applications in Vietnam and Indonesia
Ceramic conduit routing in kiln refractory lining (Vietnam — ceramics sector)
Industrial kilns in Vietnam’s ceramics manufacturing sector in Bình Dương, Đồng Nai, and Long An provinces are constructed with ceramic conduit tubes embedded in the kiln refractory lining at the design stage — these conduit tubes provide a protected routing path for the internal heating element power leads and thermocouple wiring through the kiln refractory structure, shielding the wire from direct contact with the kiln atmosphere and radiant heat from the kiln elements. The internal diameter of these embedded ceramic conduit tubes is determined at the kiln construction stage and fixed permanently in the refractory structure — a standard embedded ceramic conduit in Vietnamese kiln construction typically has an internal diameter of 8–12 mm, designed to accommodate a specific wire OD at the time of kiln commissioning.
When scheduled element replacement in Vietnamese kilns requires new wiring to be threaded through the existing embedded ceramic conduit, the replacement wire must fit through the existing conduit ID. If the original wire specification was UL 5476 or another compact-OD construction, replacing it with UL 5107 glass braid at the same AWG may result in a wire that does not pass through the conduit ID without forcing — potentially damaging the ceramic conduit or requiring the wire to be bent at angles that exceed the safe bend radius for mica tape insulation. UL 5476 compact construction allows the replacement wire to pass through the same ceramic conduit ID as the original installation, enabling element replacement without refractory rework.
Tight refractory wall penetration slots (Vietnam and Indonesia)
Industrial furnaces and kilns in Vietnam and Indonesia route internal wiring through penetration slots cut through the furnace refractory wall or insulation panel at equipment construction — slots whose cross-section geometry is determined by the tools available at the construction site and the expected wire OD at commissioning. Over multiple element replacement cycles, the penetration slot geometry typically remains fixed while the wire being threaded through it may change specification. Where the penetration slot was cut with a small cross-section — either by design for compact routing or by the limitations of the cutting tools available at a remote construction site — UL 5476’s compact OD allows the wire to pass through the same slot opening that UL 5107 would not fit through, enabling maintenance without slot enlargement work that would require furnace shutdown and insulation panel repair.
Indonesian furnace maintenance contractors operating at cement plants in East Java, petrochemical facilities in Kalimantan, and food processing plants throughout Java source UL 5476 as kabel mica harga grosir specifically for replacement wiring in existing furnaces where the penetration slot geometry constrains the replacement wire OD — factory-direct procurement from CableApex in Yangzhou provides the compact-OD specification at manufacturer pricing without the distributor markup applied to specialty mica wire through Indonesian electrical cable distribution.
Narrow structural channel wiring in furnace frame assemblies (Indonesia — furnace OEMs)
Indonesian industrial furnace manufacturers in Bekasi and Surabaya assembling multi-zone box furnaces and continuous belt furnaces route internal power wiring from the furnace external terminal cabinet through the furnace structural steel frame to the individual heating zone connections. The structural steel channels in the furnace frame — standard steel section profiles used in the frame fabrication — have fixed channel width dimensions that constrain the OD of wire that can be routed along the channel without the wire protruding above the channel edge and creating a risk of mechanical damage when panels are installed or maintained over the furnace frame.
Indonesian furnace OEMs specify UL 5476 for routing through these structural frame channels where the channel width at the wire routing section is insufficient to accommodate UL 5107 glass braid at the required AWG — the compact OD of UL 5476 allows the conductor cross-section required for the circuit current to be achieved at a smaller overall wire diameter that fits within the structural channel width constraint. New furnace builds by Indonesian OEMs for export to ASEAN markets and for domestic Indonesian industrial clients specify UL 5476 as kabel mica supplier for the frame channel routing sections where OD constraints apply.
High-temperature export equipment compact wiring assemblies (Vietnam — nhà sản xuất)
Vietnamese industrial equipment OEMs assembling compact high-temperature equipment for export — small industrial ovens, laboratory furnaces, and compact heat treatment equipment — design their equipment with minimised internal wiring space envelopes to reduce equipment footprint for export packaging and international shipping. In compact equipment designs where the internal wiring space between the heating element terminal and the external connection terminal block is tightly constrained, UL 5476’s compact OD allows the required current-carrying AWG to be routed through the available space without the larger glass braid construction of UL 5107 exceeding the available routing clearance in the compact equipment enclosure. Vietnamese equipment OEMs sourcing UL 5476 as dây mica nhà sản xuất (mica wire manufacturer supply) for compact export equipment builds procure factory-direct from Yangzhou at manufacturer pricing.
Additional applications across Vietnam and Indonesia
- Compact industrial heat treatment salt bath furnace internal wiring — Vietnamese metalworking facilities where furnace OD constraints limit internal wire routing space
- Ceramic tube heater element connection wiring — Vietnamese and Indonesian ceramic radiant heater manufacturers where element connection geometry constrains wire OD
- Compact industrial test furnace internal wiring — Vietnamese and Indonesian materials testing laboratory equipment where equipment footprint minimisation drives compact internal wiring specifications
- Multi-zone flat furnace compact wiring runs — Indonesian industrial equipment OEMs assembling flat furnace constructions for export where zone wiring must pass through narrow inter-zone insulation sections
- Replacement wiring in imported furnace equipment — Vietnamese and Indonesian maintenance operations replacing wire in imported European and Japanese furnaces where original compact European wire OD specifications must be matched
Key Features
Product
- UL AWM Style 5476, 450°C continuous, 600V AC
- File No. E333030 — UL Follow-Up Service
- Compact OD — smaller than UL 5107 at same AWG
- Same mica tape insulation performance as UL 5107
- Nickel-plated conductor recommended for 450°C continuous
- Glass braid outer mechanical protection
- RoHS and REACH compliant
Supply for Vietnam and Indonesia
- Factory-direct from Yangzhou, China
- CIF Ho Chi Minh City — 10–14 day transit
- CIF Surabaya — 10–14 day transit
- Full UL and compliance documentation
- MOQ 500 m per AWG
- 10–15 working day lead time
- Specify AWG and conductor type on enquiry
Ordering Information
Specify AWG, conductor type (nickel-plated recommended for sustained 450°C operation), and quantity. MOQ 500 m per AWG. UL 5476 compliance documentation and RoHS Declaration supplied with every order. For standard open routing at the same 450°C / 600V specification with larger OD, see UL 5107. For flat-profile routing, see UL 5334. Sample from 10 m.
Request CIF Ho Chi Minh City or CIF Surabaya pricing. Provide AWG, quantity, and destination port. We respond within 24 hours. Contact us.
Why CableApex for Vietnam and Indonesia
CableApex manufactures UL 5476 mica tape wire under UL Follow-Up Service File No. E333030 in Yangzhou, China. Factory-direct export to Vietnam and Indonesia — CIF Ho Chi Minh City or CIF Surabaya, 10–14 day transit. Full UL compliance documentation for equipment OEM qualification and furnace maintenance procurement. No distributor margin on factory-direct orders. Contact us within 24 hours.