UL 1911 High Voltage Wire — 250°C 50,000V DC Gas Ignitor Systems — Vietnam Indonesia

UL AWM Style 1911 · up to 250°C · up to 50000V DC · 24–10 AWG · any-material insulation · framework specification · horizontal flame · UL Recognized Component · internal wiring of electronic gas ignitor systems · CIF Ho Chi Minh City / CIF Surabaya · 24h quote

UL 1911 High Voltage Wire — 250°C / 50,000V DC / Gas Ignitor Systems — Vietnam and Indonesia

UL AWM Style 1911 is a high-voltage wire specification rated up to 250°C and up to 50,000V DC under UL Subject 758. The insulation material is not fixed — any UL-accepted material may be used, with the specific construction confirmed at time of production based on the required temperature and voltage ratings. The conductor range covers 24 AWG to 10 AWG in solid or stranded round construction. The permitted use is internal wiring of electronic gas ignitor systems.

UL 1911 is a framework specification: the specific temperature rating, voltage rating, and insulation material for each product are defined by the individual insulation construction and confirmed under the UL AWM recognition at production. The 250°C and 50,000V DC values represent the maximum upper limits of the Style. Vietnamese gas equipment exporters refer to UL 1911 as dây cao áp hệ thống đánh lửa gas xuất khẩu; Indonesian suppliers refer to it as kabel tegangan tinggi DC sistem ignisi gas. Export supply: CIF Ho Chi Minh City and CIF Surabaya.

UL Recognized Component — AWM Style 1911 · Up to 250°C · Up to 50,000V DC · Any-Material Construction · 24–10 AWG · File on record
UL 1911 high voltage wire technical cross section diagram showing any-material insulation, stranded copper conductor, up to 250°C, up to 50000V DC, horizontal flame, gas ignitor systems

UL 1911 Framework Specification — Key Parameters

ParameterSpecification
UL AWM Style1911
UL Subject758, Section 1
Maximum Temperature250°C (actual rating depends on insulation construction)
Maximum Voltage50,000V DC (actual rating depends on insulation construction)
Insulation TypeAny material — confirmed at production per insulation construction
ConductorSolid or stranded round, 24 AWG – 10 AWG
Flame RatingHorizontal flame
UL RecognitionUL Recognized Component — file on record
Permitted UseInternal wiring of electronic gas ignitor systems
RoHS / REACHDocumentation available on request

High Voltage Wire Selection — UL 1911 vs UL 3304 vs UL 3573 vs UL 3239

StyleMax VoltageVoltage TypeMax TempPermitted Use
UL 330410,000VAC200°CGas range / burner ignition — protected from damage
UL 357310,000VAC200°CGas range / burner ignition — three-layer construction
UL 1911 (this page)50,000V DCDC250°CInternal wiring of electronic gas ignitor systems
UL 323960,000V DCDC200°CTV receivers / where acceptability determined by UL

How to Specify UL 1911 — What to Provide at Enquiry

UL 1911 is a framework specification — the specific insulation construction is confirmed based on your application requirements. When enquiring, please provide:

Required: AWG size · Required DC voltage rating (V DC) · Required temperature rating (°C) · Conductor type (solid or stranded) · Application description (ignition system type)

Optional: Insulation material preference · Quantity and destination port

The applicable UL 1911 insulation construction covering your specified DC voltage and temperature requirements will be confirmed at enquiry stage, with pricing provided accordingly.

UL 1911 high voltage DC wire internal wiring in capacitive discharge ignition CDI module, DC charging circuit from DC-DC converter to high voltage capacitor

Applications in Vietnam and Indonesia

Capacitive discharge ignition (CDI) system DC charging wiring — Vietnam export

Vietnamese gas equipment manufacturers and ignition system OEMs assembling capacitive discharge ignition (CDI) systems for gas appliances and industrial gas burners for export specify UL 1911 for the internal DC charging circuit wiring in the CDI ignition module. A CDI ignition system charges a high-voltage capacitor to a DC voltage — the internal wiring in the DC charging section of the CDI module, from the DC-DC converter output to the high-voltage capacitor terminals, carries this DC voltage and requires a DC-rated specification. UL 3304 and UL 3573 carry AC voltage ratings and are used for the AC ignition output side; UL 1911’s DC voltage rating covers the DC charging section where this distinction matters for UL component recognition in equipment submitted for UL listing.

Industrial gas ignition systems — Indonesia

Indonesian gas burner system manufacturers and industrial ignition system assemblers specifying UL 1911 for the internal high-voltage DC wiring in industrial gas ignition systems — where the DC voltage in the ignition charging circuit requires a DC-rated specification at the applicable voltage and temperature rating. Industrial gas turbine ignition systems and high-energy spark ignition systems for large-diameter industrial gas burners may operate with stored DC voltages in the ignition capacitor bank requiring UL 1911 certification. Confirm the specific voltage and temperature requirements at enquiry stage.

Gas appliance export wiring — Vietnam and Indonesia

Vietnamese and Indonesian gas equipment exporters assembling gas appliances and commercial gas cooking equipment for export to markets requiring UL listing specify UL 1911 for internal high-voltage DC wiring sections of their ignition systems — where the DC voltage in the ignition circuit requires a DC-rated AWM specification for UL component recognition. The 250°C maximum temperature rating provides thermal margin for wire routing locations in gas appliance ignition system assemblies near the burner and combustion chamber, where applicable.

Additional applications

  • Commercial kitchen gas range CDI ignition module internal DC wiring
  • Gas water heater electronic ignition system DC charging circuit wiring
  • Industrial furnace high-voltage ignition system internal wiring
  • Industrial gas burner high-energy ignition system DC section wiring

Key Features

Product

  • UL AWM Style 1911, up to 250°C, up to 50,000V DC
  • UL Recognized Component — file on record
  • Designated for electronic gas ignitor systems
  • DC voltage rating — not AC
  • Conductor range: 24 AWG – 10 AWG
  • Construction confirmed to application at enquiry
  • Horizontal flame rating

Supply for Vietnam and Indonesia

  • Export supply — CIF Ho Chi Minh City
  • Export supply — CIF Surabaya
  • Transit approx. 10–14 days
  • UL compliance documentation on request
  • MOQ 500 m per specification
  • Lead time confirmed at enquiry stage

UL 1911 high voltage wire cut end macro showing thick insulation wall and stranded copper conductor cross section, up to 250°C 50000V DC

Ordering Information

UL 1911 is a custom-specification product. Provide AWG, required DC voltage rating, required temperature rating, application description (ignition system type), quantity, and destination port. Construction and pricing confirmed at enquiry stage. For 10,000V AC ignition wire with fixed specification, see UL 3304 or UL 3573. For general high-voltage DC wire up to 60,000V DC, see UL 3239. UL compliance documentation available on request. Response within 24 hours.

Request pricing for UL 1911. Provide AWG, DC voltage rating, temperature rating, and gas ignition system application details. Response within 24 hours. Contact us.

Scroll to Top