UL 1056 Lead Wire 12 AWG · PVC · 105°C · 600V Refrigerating Equipment

UL 1056 · 105°C maximum · 600 Vac · 12 AWG stranded (style range 20–10 AWG) · Extruded PVC 60 mils minimum average wall · Horizontal flame; VW-1 vertical flame test available · Optional 60°C / 80°C oil resistant · UL Recognized Component — file on record · Internal wiring of indoor or outdoor refrigerating equipment · Quotes within 12 hours

Category:

UL 1056 Lead Wire 12 AWG — 105°C, 600 Vac, Heavy-Wall PVC for Refrigerating Equipment Main Circuits

UL 1056 in 12 AWG is a stranded single-conductor lead wire with extruded PVC insulation, rated 105°C maximum at 600 Vac, recognised for internal wiring of indoor and outdoor refrigerating equipment. As the heaviest gauge commonly specified within the UL 1056 range, 12 AWG serves as the lead wire connecting compressor terminals, main contactors and primary distribution points where current demand exceeds what 14 or 16 AWG can comfortably carry. CableApex supplies UL 1056 12 AWG as a UL Recognized Component — file on record.

UL 1056 12 AWG technical cross-section diagram, PVC 60 mils minimum average wall, 105C 600V lead wire

UL Recognized Component — file on record. Style 1056 appliance wiring material evaluated under UL Subject 758.

When to Specify 12 AWG Instead of 14 AWG

Consideration14 AWG12 AWG (this page)
Typical roleMotor lead, secondary feedMain compressor lead, primary distribution
Current headroomModerateHigher — suits inrush-heavy compressor starts
Run length toleranceStandardBetter for longer runs at same voltage drop
PVC wall & rating105°C / 600 Vac, 60 mils avg105°C / 600 Vac, 60 mils avg (identical)

UL 1056 12 AWG Specifications

ItemSpecification
UL Style1056 — single conductor with extruded insulation
Temperature Rating105°C maximum
Voltage Rating600 Vac
Conductor12 AWG, stranded only (style range 20–10 AWG stranded)
InsulationExtruded PVC, 60 mils minimum average thickness, 54 mils minimum at any point
Flame RatingHorizontal flame; VW-1 vertical flame test available
Oil RatingOptional — 60°C or 80°C oil resistant
UL RecognitionUL Recognized Component — file on record
MarkingPer UL Subject 758 marking requirements
Permitted UseInternal wiring of indoor or outdoor refrigerating equipment
RoHS / REACHDocumentation available on request

UL 1056 12 AWG PVC lead wire connected to compressor main terminal inside refrigerating equipment

Applications

Within its permitted use — internal wiring of indoor or outdoor refrigerating equipment — UL 1056 12 AWG serves as a lead wire for main compressor terminal connections, primary contactor feeds and internal distribution points where the combination of high inrush current at compressor start-up and continuous run current calls for a larger conductor cross-section than 14 AWG provides. It suits both indoor evaporator-section wiring and outdoor condensing unit installations under the same UL recognition. Where the wiring contacts refrigerant oil, specify the 60°C or 80°C oil-resistant option. For applications outside refrigerating equipment, confirm application suitability before specifying.

Key Features

  • Heaviest stranded gauge in the UL 1056 range for main circuit leads
  • Higher current headroom than 14 AWG for compressor inrush loads
  • Same 60 mils average PVC wall and 105°C / 600 Vac rating across the range
  • Optional 60°C or 80°C oil resistant rating
  • Horizontal flame; VW-1 vertical flame test available
  • UL Recognized Component — file on record

Macro cut end of UL 1056 12 AWG lead wire showing heavy PVC insulation wall and stranded copper conductor

Request a Quote

CableApex supplies UL 1056 12 AWG from 100 m per color and responds to B2B inquiries within 12 hours with pricing, oil-rating option, lead time and packing details. Submit your specification through the form below.