UL 1333 FEP High Temp Wire 24 AWG · 150°C · 300V

UL 1333 · 150°C maximum · 300 Vac; optional 600 V peak electronic tag · 24 AWG solid, stranded or Litz cable magnet wire (style range 30–10 AWG) · Extruded FEP 13 mils minimum average wall · Optional covering: FEP 10 mils minimum, or glass braid 7 mils minimum · Horizontal flame; VW-1 vertical flame test available · Optional 80°C oil and gasoline resistance · UL Recognized Component — file on record · Internal wiring of appliances · Quotes within 12 hours

Category:

UL 1333 FEP High Temp Wire 24 AWG — Fine Conductor with a Proportionally Generous 13-mil Wall

UL 1333 in 24 AWG is a single-conductor appliance wiring material with extruded FEP insulation, rated 150°C maximum at 300 Vac with a horizontal flame rating. The style applies a single wall figure across its whole 30 AWG to 10 AWG range — 13 mils minimum average, 12 mils minimum at any point — and at 24 AWG that wall is proportionally generous relative to the conductor beneath it. The result is a fine-gauge wire with more mechanical margin than its slim outside diameter would suggest. CableApex supplies UL 1333 24 AWG as a UL Recognized Component — file on record.

UL 1333 24 AWG insulation to conductor ratio diagram comparing 13 mil FEP wall across three FEP styles

UL Recognized Component — file on record. Style 1333 appliance wiring material evaluated under UL Subject 758.

Why the Wall-to-Conductor Ratio Matters at Fine Gauges

Fine conductors are the ones most easily damaged in an assembly. A 24 AWG lead has little copper to resist a clamp tightened past its stop, a pinch against a sheet-metal edge, or the point load where a cable tie crosses a bracket corner. Whether the wire survives that treatment depends less on the conductor than on how much insulation sits between it and the object pressing on it.

Because UL 1333 does not scale its wall down for finer conductors, a 24 AWG lead in this style carries the same 13 mils of FEP as a 10 AWG lead. Against the conductor diameter, that produces a high insulation proportion — the polymer makes up a large share of the finished cross-section. Combined with the mechanical characteristics of FEP itself, which resists cold flow under sustained pressure better than softer thermoplastics, the fine sizes in this style hold up to clamping and edge contact well for their gauge. That is a different proposition from a thin-wall PVC signal wire of similar outside diameter, where both the wall and the material work against it.

24 AWG Across the Three FEP Styles

At 24 AWGUL 1333 (this page)UL 1331UL 1330
FEP wall13 mils avg / 12 mils min20 mils avg / 18 mils min20 mils avg / 18 mils min
Temperature150°C150°C200°C
Voltage300 Vac, 600 V peak tag600 Vac600 Vac
Finished diameterSlimmestLargerLarger
Best suited toDense sensor and signal runs at 300 V class600 V circuits needing more wall600 V circuits above 150°C

UL 1333 24 AWG Specifications

ItemSpecification
UL Style1333 — single conductor with extruded insulation
Temperature Rating150°C maximum
Voltage Rating300 Vac; tag may also indicate 600 Volts Peak for electronic use only
Conductor24 AWG, solid or stranded, or Litz cable magnet wire, R/C (OBMV2) rated minimum 150°C (style range 30–10 AWG)
InsulationExtruded FEP, 13 mils minimum average thickness, 12 mils minimum at any point
Optional CoveringExtruded FEP, 10 mils minimum at any point; or glass braid, 7 mils minimum at any point
Flame RatingHorizontal flame; VW-1 vertical flame test available
Oil RatingOptional — 80°C oil resistant
Gasoline ResistanceOptional
UL RecognitionUL Recognized Component — file on record
MarkingPer UL Subject 758 marking requirements; Litz product additionally marked “Litz conductors are manufactured using solderable magnet wire”
Permitted UseInternal wiring of appliances
RoHS / REACHDocumentation available on request

UL 1333 24 AWG FEP sensor lead clamped against bracket inside appliance high temperature compartment

Fine Leads in a 150°C Environment

A 24 AWG conductor carries little current, so self-heating contributes almost nothing to its operating temperature — whatever the lead reaches is essentially what the surrounding environment imposes on it. That makes fine gauges the sizes most exposed to the thermal condition of their routing path rather than to their own electrical loading, and it is why sensor and thermostat leads so often set the temperature class for an entire harness. Where those leads run through a compartment measured within 150°C, UL 1333 at 24 AWG provides the matching component recognition without the diameter of a 600 V class style. Where the same run exceeds 150°C at any point under worst-case operation, UL 1330 at 200°C is the correct style for that lead even if the rest of the harness does not need it.

Applications

Within its permitted use — internal wiring of appliances — UL 1333 24 AWG suits sensor and thermostat leads, fine signal conductors and low-current control wiring in appliances operating at 300 Vac in zones reaching 150°C, and internal electronic circuits where the 600 V peak tag applies. The slim finished diameter suits dense bundles and tight routing; the proportionally generous wall gives more clamping and edge-contact margin than the diameter implies. Litz construction is available at this gauge for fine high-frequency winding leads. Optional 80°C oil resistance and optional gasoline resistance are available where lubricant or fuel contact is expected. For applications outside internal appliance wiring, confirm application suitability before specifying.

Key Features

  • 13 mils wall on a 24 AWG conductor gives a high insulation proportion
  • FEP resists cold flow under sustained clamp pressure better than soft thermoplastics
  • Slimmest finished diameter of the three FEP styles at this gauge
  • Solid, stranded or Litz cable magnet wire conductor construction
  • 300 Vac base rating with optional 600 V peak electronic use tag
  • UL Recognized Component — file on record

Macro cut end of UL 1333 24 AWG showing generous 13 mil FEP wall proportion around fine copper conductor

Request a Quote

CableApex supplies UL 1333 24 AWG from 100 m per color and responds to B2B inquiries within 12 hours. Specify conductor construction (solid, stranded or Litz), colors, covering option, the 600 V peak tag if required, and any oil or gasoline requirements through the form below.

Other UL 1333 sizes: 18 AWG · 20 AWG · 22 AWG