UL 10362 24 AWG PFA Wire for High-Temperature Sensor Internal Wiring
UL AWM Style 10362 24 AWG PFA wire, rated 250°C and 600 Vac, is a specific conductor-size configuration within Style 10362’s broader 30 AWG–4/0 AWG range, commonly specified for internal wiring inside sensor, monitoring, and thermal-control equipment where the internal environment runs consistently hot. This page focuses on the 24 AWG SKU — its confirmed PFA insulation thickness, dimensional and electrical scope, and what still needs to be specified in an RFQ — rather than a general overview of the full Style 10362 range.

The Confirmed UL 10362 24 AWG Construction
| Parameter | UL 10362 |
|---|---|
| UL AWM Style | 10362 |
| Description | Single Conductor with Extruded Insulation |
| Featured Conductor Size | 24 AWG |
| Style Conductor Range | 30 AWG – 4/0 AWG, solid or stranded |
| Temperature Rating | 250°C |
| Voltage Rating | 600 Vac |
| Insulation | Extruded PFA |
| 24 AWG Insulation Thickness | 10 mils min. average / 8 mils min. at any point (30–10 AWG group) |
| UL-Defined Use | Internal Wiring |
10 Mil Minimum-Average PFA Insulation at 24 AWG
24 AWG falls within UL 10362’s 30–10 AWG construction group, which specifies extruded PFA insulation at 10 mils minimum average thickness and 8 mils minimum thickness at any point. This is distinct from the Style’s other groups — the 8–2 AWG group specifies 30 mils / 27 mils, and the 1–4/0 AWG group specifies 45 mils / 41 mils — and this page uses only the values applicable to the featured 24 AWG size. This page does not convert these values into an invented finished outside diameter — conductor geometry and manufacturing tolerances are order-specific.

Sensor and Monitoring Equipment Internal Wiring
The confirmed UL 10362 use is Internal Wiring. Realistic commercial contexts for this 24 AWG configuration include sensor lead wiring in heat-exposed equipment, internal control and monitoring assemblies, thermal-sensing systems inside industrial equipment, and OEM internal sensor wiring in high-temperature sections. “Sensor wiring” and “monitoring equipment” are commercial application contexts a buyer brings to this page — they are not a separate UL-defined Use category, and this page does not automatically describe UL 10362 as thermocouple wire, thermocouple extension wire, or instrumentation cable unless a specific ordered construction independently confirms that classification.
Dimensional Requirements: An RFQ Field, Not a Published Nominal OD
Where a sensor assembly has a tight routing allowance or a specific connector clearance, the required maximum finished OD, terminal or connector restriction, and routing-space constraint should be provided in your RFQ. This page does not publish an invented nominal outside diameter for 24 AWG — finished OD depends on the actual conductor construction and is confirmed for the ordered specification.

Current-Carrying Capacity Is Not Defined by This Page
This page does not publish a generic ampacity figure for 24 AWG, and does not infer allowable current from the 24 AWG conductor size, the 600 Vac voltage rating, or the 250°C temperature rating — these are separate parameters. Current-carrying suitability depends on the actual equipment design and installation and must be evaluated accordingly.
What UL 10362 Does Not Automatically Define
The Style data does not automatically define: conductor material, conductor plating, strand count, strand diameter, conductor resistance, current rating, ampacity, finished OD, bend radius, flexibility class, sensor type, signal type, stock, MOQ, lead time, reel length, or production capacity. These are RFQ fields unless separately documented — none of them are invented on this page.
RFQ Checklist for UL 10362 24 AWG Sensor Internal Wire
To request an accurate quotation, please specify:
- UL AWM Style 10362
- 24 AWG
- Solid or stranded requirement
- Conductor material / plating, if specified
- 250°C requirement
- 600 Vac requirement
- Insulation colour
- Finished OD limit, if controlled
- Sensor or monitoring equipment application
- Actual local operating temperature
- Terminal or connector requirement
- Quantity
- Reel or cut-length requirement
- Destination
- Documentation requirement
Applicable RoHS / REACH documentation can be confirmed according to the ordered construction.
See the UL10362 PFA Wire category, our Fluoropolymer Wire range, or our AWM Wire category for other conductor sizes and configurations within this Style.