UL 1007 24 AWG Stranded Copper Hook-Up Wire (80°C / 300V)

UL AWM Style 1007 · 24 AWG · selected stranded-copper construction · PVC hook-up wire · 80°C · 300 Vac · extruded PVC, 15 mils min avg / 13 mils min at any point · bare or tinned conductor finish confirmed at order · horizontal flame; VW-1 vertical flame test available · internal wiring of appliances · optional 60°C or 80°C Oil construction subject to the qualified ordered construction · OEM factory supply · conductor and processing specifications confirmed during quotation

Categories: ,

UL 1007 24 AWG — Selected Stranded-Copper Construction

This page covers UL AWM Style 1007 supplied at 24 AWG with a selected stranded-copper construction. UL Style 1007 permits either solid or stranded conductor across its scope, so stranded is a construction choice on this page rather than a Style requirement. The bare or tinned conductor finish is likewise confirmed according to the ordered construction.

The full UL Style 1007 range is 32 AWG through 16 AWG, rated 80°C at 300 Vac with extruded PVC insulation at 15 mils minimum average and 13 mils minimum at any point. The stated use is internal wiring of appliances. At 24 AWG this construction sits in the fine-wire portion of the range. For the full Style overview and other conductor sizes, see UL 1007 Wire.

UL AWM Style 1007 24 AWG cross-section technical diagram showing stranded copper conductor and 15 mils extruded PVC insulation per UL Subject 758

UL AWM Style 1007 — Specifications

UL AWM Style1007
UL Subject / Section758, Section 1
Temperature rating80°C
Voltage rating300 Vac
Conductor range (Style scope)32 AWG – 16 AWG, solid or stranded
Conductor (this page)24 AWG, selected stranded-copper construction; bare or tinned finish confirmed at order
InsulationExtruded PVC
Minimum average insulation thickness15 mils (0.38 mm)
Minimum insulation at any point13 mils (0.33 mm)
Optional construction60°C or 80°C Oil — optional, depends on the qualified ordered construction
Flame ratingHorizontal flame; VW-1 vertical flame test available
MarkingPer UL Subject 758 marking requirements; confirmed for the qualified ordered construction
Use per UL Style fileInternal wiring of appliances; tags may indicate 600 V Peak — For Electronic Use Only
RoHS / REACHRequirements confirmed according to ordered materials and documentation requirements

The 600 V Peak statement is an optional tag marking for electronic-use conditions rather than the working voltage rating. The normal rating is 300 Vac.

Specifying 24 AWG

24 AWG is selected when the equipment design, the electrical requirement, the available routing space and the termination system in use specifically call for this conductor size. None of these is established by the conductor size alone, and current-carrying requirements in particular should be confirmed against the applicable engineering data for the equipment rather than inferred from the Style rating.

Where 24 AWG is confirmed, the remaining construction detail is settled at order stage. The UL Style file defines the insulation and the conductor size range but not the conductor material, finish or strand construction:

  • Solid or stranded. Both are within the UL Style 1007 scope. This page covers the stranded construction; solid is available where the routing path is fixed and the termination method accommodates it.
  • Conductor finish. Bare or tinned copper is confirmed during quotation, and is normally driven by the termination process used in the assembly.
  • Strand construction. Where your assembly requires a specific strand configuration, specify it at enquiry so it can be confirmed against production capability.

Appliance Internal Wiring Applications

The UL Style 1007 file states the use as internal wiring of appliances. At 24 AWG, 80°C and 300 Vac, this construction is typically specified for:

  • Protected internal appliance interconnections within the appliance housing
  • Appliance switch and terminal leads at internal connection points
  • Compact internal routing inside appliance assemblies where the available channel space suits a fine-gauge construction
  • OEM appliance production where 24 AWG is a repeated internal lead size across the build

UL Style 1007 is not supplied or positioned as field wiring, building wire, external wiring, industrial control wiring, general wiring harness cable, motor lead wire or power cable. Suitability for a specific appliance design depends on the equipment, the routing arrangement, the ordered construction and the applicable equipment-level evaluation — not on the temperature and voltage ratings being sufficient on their own.

UL AWM Style 1007 24 AWG PVC wire routed through compact internal channels inside an appliance assembly, 80°C 300 Vac protected internal wiring

Production Notes for Harness Processing

UL 1007 24 AWG wire can be supplied for OEM harness production where the finished assembly uses the wire as appliance internal wiring. Where harness processing is part of your operation, the following points are relevant:

  • Stripping. Consistent PVC extrusion can support repeatable stripping during confirmed production runs. Confirm the insulation dimensions so stripper settings can be calibrated to the actual ordered construction, particularly at fine gauges where blade clearance is tight.
  • Cutting. Fixed-length cutting can be arranged where the assembly uses repeated lead lengths. Specify the required tolerance at enquiry.
  • Crimping. Confirm the terminal hardware so the conductor construction can be checked against the crimp barrel range for the selected terminals.
  • Soldering. Where soldering is part of the process, a tinned conductor finish should be specified at the order stage.
  • Stranded conductor. Stranded construction may be preferred where routing and termination flexibility are important during harness processing.
  • Colour identification. High-mix harness builds typically require several colours. Send the colour list with quantity per colour rather than a single total.
  • Reel and spool supply. Confirm the format and length your assembly line works with.

Supplying wire for harness production does not change the Style boundary — the finished assembly must be used as appliance internal wiring.

Optional Oil Construction

UL Style 1007 permits an optional 60°C or 80°C Oil construction. Not all UL 1007 24 AWG wire carries this — where oil performance is required at the wire location, the optional construction must be specified at enquiry, and it depends on the qualified ordered construction. Confirm the requirement and the applicable marking before production.

UL Marking and Order Documentation

CableApex supplies UL AWM Style 1007 construction from factory production. UL marking and Style-specific documentation depend on the qualified ordered construction, and both should be confirmed during quotation. Where RoHS, REACH or other documentation is required, specify the requirement at enquiry so availability can be confirmed for the ordered materials and construction.

Buyer Checklist for Quotation

Send the following so a quotation can be prepared against a defined construction:

  • 24 AWG confirmation
  • Conductor type — solid or stranded requirement
  • Conductor finish — bare or tinned
  • Required strand construction, if your assembly specifies one
  • Insulation colour, with quantity per colour
  • Total quantity
  • Reel or spool length
  • Cut length and tolerance, if applicable
  • Stripping requirement
  • Crimping or soldering process used in the assembly
  • Marking requirement
  • Documentation requirement
  • Destination

UL AWM Style 1007 24 AWG stranded copper wire stripped end and crimped terminal detail for harness processing

Related UL AWM Styles

Buyers specifying UL 1007 24 AWG may also consider: UL 1007 Wire for the full 32–16 AWG Style range and other conductor sizes; UL 1015 (80–105°C / 600 Vac or 750 Vdc, extruded PVC, 30 AWG–2000 kcmil, 30 mils min avg wall — the higher-voltage PVC Style where 300 Vac is insufficient); and UL 1569 (80–105°C / 300 Vac, extruded PVC, 30–2 AWG, 15 mils min avg wall — same 300 Vac class and thin wall with a 105°C temperature option). The wider ranges are available under PVC Insulated Wire and AWM Wire.

Scroll to Top