UL 1332 24 AWG FEP Wire — 200°C 300V for Compact Appliance Internal Wiring

UL AWM Style 1332 24 AWG FEP wire, rated 200°C and 300 Vac, extruded FEP insulation at 13 mils minimum average / 12 mils minimum at any point, solid or stranded round conductor, Horizontal flame, for internal wiring of appliances. Commonly specified for compact appliance internal wiring where the BOM controls conductor size — finished OD and routing-space constraints should be confirmed separately. Optional covering and optional oil / gasoline resistance available where specifically qualified. Conductor material, plating, colour, and finished OD confirmed per order.

UL 1332 24 AWG FEP Wire for Compact Appliance Internal Wiring

UL AWM Style 1332 24 AWG FEP wire, rated 200°C and 300 Vac, is a specific conductor-size configuration within Style 1332’s broader 30 AWG–10 AWG range, commonly specified for internal wiring inside compact appliance assemblies where the BOM controls conductor size and available routing dimensions must be confirmed before quotation. This page focuses on the 24 AWG SKU — its confirmed FEP insulation requirement, dimensional scope, and what still needs to be specified in an RFQ — rather than a general article about routing behavior.

UL Style 1332 24 AWG FEP wire cross-section diagram showing conductor, 13 mil FEP insulation, and optional covering

The Confirmed UL 1332 24 AWG Construction

ParameterUL 1332
UL AWM Style1332
DescriptionSingle Conductor with Covering
Featured Conductor Size24 AWG
Style Conductor Range30 AWG – 10 AWG, solid or stranded round
Temperature Rating200°C
Voltage Rating300 Vac
FlameHorizontal flame
InsulationExtruded FEP, 13 mils min. average / 12 mils min. at any point
Optional CoveringExtruded FEP, 2 mils or heavier; or glass braid, 7 mils or heavier
Optional Resistance RatingsOil Resistant 80°C; Gasoline Resistant
UL-Defined UseInternal wiring of appliances

13/12 Mil FEP Insulation at 24 AWG

The confirmed insulation requirement for UL 1332 is extruded FEP at 13 mils minimum average thickness and 12 mils minimum thickness at any point, applying across the Style’s full 30–10 AWG range — this page does not invent a different thickness specific to 24 AWG, since the Style’s insulation requirement is not tiered by conductor size group. This page does not convert this figure into an invented finished outside diameter, and does not assign a friction coefficient, abrasion rating, or any other unsupported physical-handling property to this figure — conductor geometry and handling characteristics are order-specific and are not established by the Style-level record.

UL 1332 24 AWG FEP wire routed inside compact appliance enclosure for internal wiring connections

Compact Installation Dimensions: An RFQ Field, Not an Assumed Property

This page does not describe UL 1332 as inherently easier to route, lower-friction, or better suited to tight spaces than another AWM construction — no such property is established by the Style-level record. What actually determines fit within a compact assembly is the confirmed conductor size, finished OD, and the buyer’s own routing-space, connector-cavity, or grommet constraint. If your compact appliance design has a specific dimensional limit, state the required maximum finished OD, connector or grommet restriction, and routing-space constraint in your RFQ — this page does not publish an invented nominal OD for 24 AWG.

Optional Covering and Resistance Ratings

UL Style 1332 permits an optional covering over the FEP-insulated conductor — either extruded FEP at 2 mils or heavier, or glass braid at 7 mils or heavier — and optional Oil Resistant 80°C and Gasoline Resistant ratings. None of these are standard on every UL 1332 24 AWG order; this page does not describe every unit as covered, oil resistant, or gasoline resistant by default. If your application requires any of these, specify it explicitly in your RFQ.

What UL 1332 Does Not Automatically Define

The Style data does not automatically define: conductor material, plating, strand count, strand diameter, conductor resistance, ampacity, current rating, finished OD, bend radius, flexibility class, friction coefficient, abrasion rating, standard colour, MOQ, lead time, stock, reel length, or production capacity. These require separate confirmation — none of them are invented on this page.

Macro cross-section of UL 1332 24 AWG FEP wire showing fine stranded conductor and thin extruded FEP wall

RFQ Checklist for UL 1332 24 AWG Wire

To request an accurate quotation, please provide:

  • UL AWM Style 1332
  • 24 AWG
  • Solid or stranded
  • Conductor material, if controlled
  • Conductor plating, if controlled
  • 200°C requirement
  • 300 Vac requirement
  • Insulation colour
  • Maximum finished OD, if controlled
  • Optional covering, if required
  • Optional oil / gasoline qualification, if required
  • Compact appliance / internal wiring context
  • Terminal or connector requirement, if relevant
  • Quantity
  • Packaging
  • Destination
  • Documentation requirement

Applicable RoHS / REACH documentation can be confirmed according to the ordered construction.