UL 5476 Multi-Core Mica Glass Braid Cable — 450°C 600V for Protected High-Temperature Internal Wiring

UL AWM Style 5476 multi-core mica glass braid cable, 450°C, 600 Vac, 30 AWG–4/0 AWG, solid or stranded, mica tape with treated glass braid. Two or more conductors may be cabled together, max. overall assembly diameter 1.500 in., with optional binder, fiberglass fillers, overall glass braid and metallic shield. For internal wiring — not for repeated flexing, protected from mechanical abuse. Construction and documentation confirmed by order.

UL 5476 Multi-Core Mica Glass Braid Cable Overview

This page covers UL AWM Style 5476 mica tape and treated glass braid insulated cable, supplied by CableApex as a factory-direct manufacturer. UL Style 5476 covers a conductor range of 30 AWG through 4/0 AWG, solid or stranded, and permits two or more qualifying conductors to be cabled together into a multiple-conductor assembly. This page’s primary focus is the multiple-conductor configuration, supporting our Multi-core Cable range; buyers requiring a single-conductor UL 5476 construction should confirm that requirement separately during quotation.

UL 5476 multi-core mica glass braid cable is rated 450°C and 600 Vac, built from mica tape with treated glass braid, for internal wiring where not subjected to repeated flexing and protected from mechanical abuse. Core count, conductor material and finish, shield requirement, and packaging are confirmed according to the ordered specification.

UL Style 5476 multi-core cable cross-section diagram showing individually insulated conductors and multi-conductor assembly construction

450°C / 600 Vac UL Style 5476 Rating

ParameterUL Style 5476
ConstructionSingle or multiple conductor with other-than-extruded insulation
Rated Temperature (Maximum)450°C
Voltage Rating600 Vac
Flame RatingHorizontal flame; VW-1 vertical flame test available
Conductor Size Range (Style)30 AWG – 4/0 AWG, solid or stranded
InsulationMica tape with treated glass braid — silicone varnish or TFE finish
Optional Intermediate MaterialOptional material may be applied between mica tape and glass braid per qualified construction (material not specified here)
AssemblyTwo or more conductors may be cabled together; max. overall assembly diameter 1.500 in.
Optional Assembly MaterialsMica glass binder, fiberglass fillers, overall treated glass braid
Optional Shield36–30 AWG, Type A Nickel or 27% min. nickel-coated copper
MarkingGeneral — company name, model designation and UL Recognized Component Mark — file on record
Use per UL Style fileInternal wiring where not subjected to repeated flexing and protected from mechanical abuse; acceptability including current-carrying capacity determined by UL
RoHS / REACHConfirmed during quotation according to ordered materials and documentation requirements

Mica Tape and Treated Glass Braid Construction

Each conductor is insulated with mica tape, covered by a treated glass braid finished with silicone varnish or TFE finish according to the qualified construction. This is a mica-and-glass-braid construction — not a silicone rubber, PTFE, FEP, PFA, PVC, or XLPE insulated product. Silicone varnish is a treatment applied to the glass braid, not a silicone rubber primary insulation, and a TFE finish is not the same as a PTFE-insulated conductor. The UL Style record also permits an optional material to be applied between the mica tape and the glass braid according to the qualified construction; the supplied documentation does not identify that material, so we do not name or describe it here — it is confirmed only where a specific construction requires it.

UL 5476 Construction Thickness by AWG Range

Conductor SizeMica Tape (min. avg.)Treated Glass Braid (min. avg.)
30–12 AWG17 mils7 mils
11–4 AWG21 mils15 mils
3 AWG–4/0 AWG26 mils20 mils

These are the exact minimum average construction values from the UL Style 5476 record and do not translate into an invented finished conductor or cable outside diameter. Conductor material, plating, strand count, and resistance are not established by the Style-level record and are confirmed according to your ordered specification.

UL 5476 multi-core mica glass braid cable routed as protected internal wiring, mechanically protected high-temperature installation

Multiple-Conductor Cable Assembly

Two or More Conductors Cabled Together

UL Style 5476 permits two or more qualifying conductors to be cabled together, with a maximum overall assembly diameter of 1.500 inches. This 1.500-inch figure is the maximum permitted assembly diameter, not a standard finished O.D. — actual assembly diameter depends on core count, conductor size, and construction, and is confirmed for the ordered configuration. Core count is not fixed by the Style and must be specified according to your required assembly; this page does not present fixed 2-core, 3-core, 4-core, or other preset specifications.

Optional Binder, Fiberglass Fillers and Overall Treated Glass Braid

Depending on the qualified ordered construction, the cabled assembly may employ a mica glass binder and/or fiberglass fillers, and may have an overall treated glass braid. These are optional, order-specific features rather than standard components of every UL 5476 multi-core assembly — specify which, if any, are required when requesting a quotation.

Optional Nickel / Nickel-Coated Copper Shield

UL Style 5476 permits an optional shield of 36–30 AWG strands, using Type A Nickel or 27% minimum nickel-coated copper. This is an optional shield construction, distinct from the primary current-carrying conductors — the primary conductor material is not established as nickel or nickel-coated copper by this optional shield feature. We do not publish shielding effectiveness, EMI attenuation, transfer impedance, or braid coverage for this optional shield. If your application requires it, specify the shield material when requesting a quotation.

Protected High-Temperature Internal Wiring

UL Style 5476 is designated for internal wiring where not subjected to repeated flexing and protected from mechanical abuse. This is the application boundary for the product supplied from this page: protected high-temperature internal wiring, fixed high-temperature internal connections, and protected multi-conductor internal cable assemblies. It is not intended as building wire, field wiring, branch-circuit cable, tray cable, direct-burial or outdoor cable, or a portable, continuous-flex, or control-cabinet field cable, and this page does not position the product as thermocouple extension or instrumentation cable.

Repeated Flexing and Mechanical Protection Limitations

The UL Style use statement explicitly excludes repeated flexing and requires protection from mechanical abuse. UL 5476 is not described on this page as flexible, high-flex, super-flexible, continuous-flex, or a drag-chain or robotics cable. This product is not positioned for exposed workshop-floor routing, dragging, mechanical impact, crushing, or exposed outdoor routing, and the optional glass braid or shield is not a substitute for the application-level mechanical protection the Style requires. We do not publish a bending radius, flex-cycle rating, or vibration-endurance figure, as none is confirmed by the supplied UL record.

UL Marking and Documentation Requirements

Qualifying UL AWM Style 5476 constructions can be supplied through the relevant partner manufacturing scope associated with the applicable UL Recognized Component file on record. UL marking and related documentation depend on the specific qualified construction ordered; not every configuration automatically carries a UL Mark, and marking requirements should be confirmed when requesting a quotation. The UL use statement specifically references acceptability including current-carrying capacity — we do not publish an ampacity table or infer current capacity from AWG; applicable current-carrying capacity depends on the actual conductor size, assembly construction, and equipment conditions. We do not guarantee that a given shipment will pass a customer’s internal or third-party audit, certification review, or project bidding requirement.

RoHS and REACH are separate regulatory frameworks from UL recognition and are not treated as equivalent certifications on this page. Applicable RoHS / REACH documentation, where required, is confirmed according to the ordered materials and your documentation requirements.

Macro cross-section of UL 5476 multi-core cable showing mica-tape-insulated conductors and treated glass braid layers

Ordering UL 5476 Multi-Core Cable

To provide an accurate quotation for UL 5476 multi-core mica glass braid cable, please specify:

  • Required AWG size within the 30 AWG–4/0 AWG Style range
  • Solid or stranded conductor
  • Conductor material and finish requirement
  • Number of conductors
  • Mica tape / glass-braid construction requirement
  • Optional intermediate layer requirement, where applicable
  • Optional mica glass binder requirement
  • Optional fiberglass filler requirement
  • Optional overall treated glass braid requirement
  • Optional shield requirement, and shield material if required
  • Order quantity
  • Packaging requirement
  • UL marking requirement, if applicable
  • Documentation requirements, including RoHS / REACH if needed
  • Shipping destination

Send this information and we respond with a quotation within 12 business hours. Production lead time depends on the confirmed construction and order quantity, and shipping options and applicable Incoterms are confirmed during quotation according to destination.

This construction supports our Multi-core Cable range. For other constructions within this Style, see our UL 5476 Mica Wire category.

Scroll to Top